CHCMQ - RAM STRIP (BULK)

  • MSDS: CHCMQ
  • Manufacturer: RAMCO SPECIALTY PRODUCTS
  • Product Name: RAM STRIP (BULK)
  • National Stock Number: 6850-00N085278
Product Identification

Product ID:RAM STRIP (BULK)
MSDS Date:11/01/1989
FSC:6850
NIIN:00N085278
MSDS Number: CHCMQ

Responsible Party
RAMCO SPECIALTY PRODUCTS
5956 STATE RD
BAKERSFIELD, CA 93308
US

Emergency Phone: 805-393-6581;800-424-9300(CHEMTREC)

Info Phone: 800-334-7071

Preparer: LINDA SHEPHERD

Cage: 0AV13

Contractor
RAMCO SPECIALITY PRODUCTS
BAKERSFIELD, CA 93308-3022 US

Telephone: 714-758-7795

Cage: 0AV13

Ingredients

METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 65-75%

OSHA PEL 500 PPM; Z-2

ACGIH TLV: 50 PPM, A2

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 10-15%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHANOL (SARA 313) (CERCLA)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: 3-5%

OSHA PEL S, 200 PPM

ACGIH TLV: S, 200 PPM/250 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL ALCOHOL; (ETHANOL)

CAS: 64-17-5

RTECS: KQ6300000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


GUIDE TO USING THIS PROD IN MOST EFTIVE WAY &

RTECS: 9999999ZZ


HEALTH. AEROSOL PRODS PRESENT LIMITED HAZ BURING

RTECS: 9999999ZZ


MIS-USE BY DELIB CONC & INHALING CONTENTS CAN BE

RTECS: 9999999ZZ


EXPOS TO TEMPS >120F & SPRAY SHOULD NOT BE DIRECTED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: EXCESS INHAL OF VAPS CAN
CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCHS & POSS
UNCON. SKIN CONT/ABSORP: PRLNGD/RPTD CONT CAN CAUSE MOD IRRIT,
DEFAT & DERM. INGEST: CAN CAUSE SEV GI IRRIT, NAUS, VOMIT & DIARR.
ASPIR OF MATL INTO LUNGS CAN CAUSE CHEM PNEUM. EYES: CAN CAUSE SEV
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONO SUPP, VOL
7, PG 194, 1987: GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994:
ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZ: IRRIT, REDNESS, TEARING & BLURRED
VISION. CHLOROCARBON MATLS HAVE PRDCED SENSIT OF MYOCARDIUM TO
EPINEPHRINE IN LAB ANIMALS & COULD HAVE A SIMILAR EFT IN HUMANS.
ADRENOMIMETICS (E.G. EPINEPH RINE) MAY BE CONTRAINDICATED EXCEPT
FORLIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES & SKIN: FLUSH EYES W/WATER LIFTING UPPER & LOWER LIDS
FOR @ LST 15 MINS. GET MED ATTN. WASH EXPOS SKIN AREAS W/SOAP &
WATER. INHAL: REMOVE TO FRESH AIR. IF BRTHG IS DFCLT, ADMIN OXYG.
GET MED ATT N IMMED. INGEST: DO NOT INDUCE VOMIT. GET MED ATTN.
ASPIR OF MATL INTO LUNGS DUE TO VOMIT CAN CAUSE CHEMICAL
PNEUMONITIS.

Fire Fighting

Flash Point Method:TOC
Flash Point:84.0F,28.9C
Extinguishing Media:DRY CHEMICAL, CO*2, FOAM.
Fire Fighting Procedures:NIOSH APPRVD PRESS DEMAND SCBA & FULL PROT
EQUIP . KEEP CNTNRS COOL. USE EQUIP SHIELDING REQD TO PROTECT PERS
AGAINST BURSTING, RUPTURING/VENTING CNTNRS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE . AT ELEVATED TEMPERATURES (>120F)
CONTAINERS MAY VENT RUPTURE OR BURST.

Accidental Release

Spill Release Procedures:SM SPILLS: MOP UP, WIPE UP OR SOAK UP IMMED.
REMOVE TO OUT DOORS. LG SPILLS: EVACUATE AREA. CONTAIN LIQUID;
TRANSFER TO CLOSED METAL CNTNRS. KEEP OUT OF WATER SUPPLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE
120F. PLEASE READ & FOLLOW PRODUCT LABEL.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIA MAY
CAUSE FORMATION OF HCL &/OR PHOSGENE . PLEASE READ & FOLLOW
DIRECTIONS O N PROD LBL. THEY ARE YOUR BEST (ING 5)

Exposure Controls

Respiratory Protection:WHERE VAPOR CONC IS 100-1000 PPM, NIOSH APPRVD
ORGANIC VAPOR RESPIRATOR. IF CONC EXCEEDS 1000PPM, NIOSH APPRVD
SELF-CONTAINED BREATHING APPARATUS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) AND/OR LOCAL
EXHAUST VENT TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:CHEM RESIST-VITON/POLYVINYL CHLORIDE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREA. WASH
HANDS BEFORE EATING.
Supplemental Safety and Health
EXPLAN OF CARCIN: TO BE CARCIN. EFTS OF OVEREXP: CHLOROCARBONS .
TOLUENE: APPEARS ON NAVY LISTING OF OCCUP CHEM REPROD HAZARDS. SEEK
CONSULTATION FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST
HAZARD LIST INFO & SAFE HNDLG & EXPOS INFO . WASTE DISP METH: IS
STRONGLY DISCOURAGED & MAY BE ILLEGAL.

Chemical Properties

Boiling Pt:B.P. Text:102F,39C
Spec Gravity:1.126 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR WATER WHITE LIQUID/MILD SWEET ODOR.
Percent Volatiles by Volume:>85

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS, ALUMINUM AND OTHER REACTIVE METALS.
Stability Condition to Avoid:DO NOT EXPOSE TO TEMPERATURES >120F.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE (SMALL
AMOUNTS).

Disposal

Waste Disposal Methods:WHEN DISPOSING OF UNUSED CONTENTS, PREFERRED
OPTIONS ARE TO SEND LICENSED RECLAIMER, PERMITTED INCINERATORS/TO
EVAP VERY SM QTYS IN COMPLIANCE W/LOC, STATE & FED REGS INCL
SUBTITLE C OF RCRA. DUMPING INTO SEWER, ON GROUND/W/ANY BODY OF
WATER(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.